MERCK 105174 Hematoxylin solution modified acc. to Gill III for microscopy

1.854,42 TL
Stok Kodu
M.105174.0500
Fiyat
42,70 EUR + KDV
Description
Catalogue Number 105174
Description HEMATOXYLIN SOLUTION MODIFIED ACC. TO GI
Overview In hematoxylin-eosin staining (H&E), the most widely used histological staining technique, nuclear staining is achieved using ready-to-use staining solutions, such as Mayer’s hemalum solution or Hematoxylin solution modified according to Gill III. These solutions do not need to be filtrated prior use and the dye is oxidized in a controlled manner, which renders the results robust and allows a brilliant differentiation of the stained structures. Counterstaining of i.e. for proteins, collagen, keratin, intercellular substances. can be performed with alcoholic or aqueous Eosin Y solution 0.5 %. A 500 ml bottle is sufficient for 1500 up to 2500 slides. It is registered as IVD and CE product.
Product Information
HS Code 3203 00 10
Physicochemical Information
Density 1.07 g/cm3 (20 °C)
pH value 2.5 (H₂O, 20 °C)
Safety Information according to GHS
Hazard Pictogram(s)

Hazard Statement(s) H318: Causes serious eye damage.
H373: May cause damage to organs through prolonged or repeated exposure.
EUH210: Safety data sheet available on request.
Precautionary Statement(s) P280: Wear eye protection.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P314: Get medical advice/ attention if you feel unwell.
Storage class 10 - 13 Other liquids and solids
WGK WGK 1 slightly water endangering
Disposal 3
Relatively unreactive organic reagents should be collected in container A. If halogenated, they should be collected in container B. For solid residues use container C.
Safety Information
Hazard Symbols Irritant
R Phrase R 41
Risk of serious damage to eyes.
S Phrase S 26-39
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.Wear eye/face protection.
Storage and Shipping Information
Storage Store at +15°C to +25°C.
Specifications
Suitability for microscopy passes test
Nuclei (Tissue section) dark blue
Cytoplasm pale greyish blue
Nuclei (Vaginal smear) blue to violet
Cyanophilic cytoplasm bluish green to green
Eosinophilic cytoplasm pink
Bu ürüne ilk yorumu siz yapın!
Bu ürünün fiyat bilgisi, resim, ürün açıklamalarında ve diğer konularda yetersiz gördüğünüz noktaları öneri formunu kullanarak tarafımıza iletebilirsiniz.
Görüş ve önerileriniz için teşekkür ederiz.
MERCK 105174 Hematoxylin solution modified acc. to Gill III for microscopy M.105174.0500
MERCK 105174 Hematoxylin solution modified acc. to Gill III for microscopy

Tavsiye Et

*
*
*
IdeaSoft® | E-Ticaret paketleri ile hazırlanmıştır.